收集于郑州大学附属肿瘤医院就诊的肝脏疾病患者70例(同时行自由呼吸Look-locker序列和屏气B1-corrected VFA序列扫描),排除不能配合屏气患者4例,最终66例患者纳入研究。分别测量66例患者Look-locker序列和屏气B1-corrected VFA序列在肝脏左叶及右叶的T1值,并比较两种成像方法所得T1值的差异,应用变异系数(coefficient of variation,CV)来评价两种成像方法的变异度,采用Bland-Altman法对医师1及医师2之间的测量结果进行对比。
To evaluate the quantitative characteristics of T1 values of left and right lobes obtained by two kinds of T1 mapping methods (free-breathing Look-locker sequence and breath-holding B1-corrected VFA sequence)
and to evaluate their variability.
Methods:
Seventy patients with liver disease were enrolled in Affiliated Cancer Hospital of Zhengzhou University Henan Cancer Hospital (both free-breathing Look-locker sequences and breath-holding B1-corrected VFA sequence scans). Four patients were excluded because of the inability to cooperate with the breath. The final 66 patients were included in the study. The T1 values of the Look-locker sequence and breath-hold B1-corrected VFA sequence in the left and right lobes of the liver were measured in 66 patients
and the differences in T1 values obtained from the two imaging methods were compared. The coefficient of variation (CV) of T1 values was compared to evaluate the reliability of these two sequences. Bland-Altman method was used to compare the measurement results between physician 1 and physician 2.
Results:
The correlation coefficients of the T1 value in left lobe was 0.961 in Look-locker and 0.884 in B1-corrected VFA respectively
and it in right lobe was 0.962 and 0.828
respectively (
P
0.001). It is no significant difference between cirrhosis and non-cirrhosis in Look-locker and B1-corrected VFA of left and right lobe of liver (
P
0.05). Compared the T1 values [(803.3980.59)10
-3
s
(777.5384.97)10
-3
s] obtained from the Look-locker sequencein the left and right lobes of the liver with the T1 values obtained from the B1-corrected VFA sequence [(869.77116.67) 10
-3
s
(852.08125.03)10
-3
s]. The difference was not statistically significant (
P
0.05;
t
=1.794
0.840). There was a statistically significant difference between the two sequences in the T1 values obtained from the left and r
ight lobes of the liver (
P
0.05
t
=14.63
15.48). The coefficient of variation of the left and right lobe of liver in Look-locker (0.100
0.109) was significantly lower than in B1-corrected VFA T1 mapping (0.134
0.147). The Bland-Altman scatter plot shows that the distribution of f values determined by the Look-locker sequence is relatively more concentrated.
Conclusion:
The T1 values obtained by using the Look-locker sequence and the B1-corrected VFA sequence for normal liver tissues are different. The change in the T1 value does not indicate liver cirrhosis. The consistency of the T1 value measured by the Look-locker sequence is assessed to be small. The image quality is more stable
Diagnostic value of simplified MRI sequence in breast diseases
The value of diffusion kurtosis imaging combined with peripheral blood inflammatory markers in predicting the pathological grading of clear cell renal cell carcinoma
A flexible segmentation network for MRI: toward accurate tumor delineation and 3D reconstruction in brain glioma
Prediction of lymphovascular invasion using multiparametric MRI habitat radiomics based on machine learning algorithms in gastric cancer
Application value of multimodal imaging technology based on CT and MRI in the diagnosis and PRETEXT staging of childhood hepatoblastoma
Related Author
HUANG Xing
LIANG Yan
YI Chuang
WANG Yan
REN Junjie
LI Weilan
BA Zhufei
LIU Tao
Related Institution
Department of Radiology, Jilin Provincial People's Hospital
Department of Medical Imaging, North China University of Science and Technology Affiliated Hospital
Department of Cardiothoracic Surgery, KaiLuan General Hospital
Department of Radiology, Cancer Hospital of Dalian University of Technology, Liaoning Cancer Hospital & Institute
Department of Computing Science and Artificial Intelligence, Liaoning Normal University